Equipment & scope
Clear scope boundaries are the cheapest risk control on a biogas project. Below is the standard battery limit for a power plant and an upgrading plant.
Gas engines
Chinese-manufactured gas engines from a proven production line, configured for POME biogas, typically 25–35% below the landed price of a European equivalent for 600–800 kW units.
| Model class | Output | Electrical efficiency | Heat recovery | Voltage |
|---|---|---|---|---|
| 300 kW | 300 kW / 375 kVA | 36–38% | ≈ 330 kW | 415 V / 50 Hz |
| 500 kW | 500 kW / 625 kVA | 35.2% | ≈ 560 kW | 415 V / 50 Hz |
| 600 kW | 600 kW / 750 kVA | 35.1% | ≈ 680 kW | 415 V / 50 Hz |
| 700 kW | 700 kW / 875 kVA | 35.2% | ≈ 790 kW | 415 V / 50 Hz |
| 800 kW | 800 kW / 1,000 kVA | ≈ 35.2% | ≈ 900 kW | 415 V / 50 Hz |
| 1,000 kW | 1,000 kW / 1,250 kVA | 35.2% | ≈ 1,150 kW | 415 V / 50 Hz |
| 1,500 kW | 1,500 kW / 1,875 kVA | 39–41% | ≈ 1,700 kW | 415 V / 50 Hz |
| 2,000 kW | 2,000 kW / 2,500 kVA | 39–42% | ≈ 2,300 kW | 11 kV option |
Indicative at full load with 60% CH₄. Final selection based on site gas data. Containerised from 300 kW to 1.5 MW.
Electrical efficiency is taken from the manufacturer gas consumption data below (≈3.50 kWh per Nm³ CH₄), which is lower than the 38–40% sometimes quoted for Chinese units.
Generator end · option
POME gas output is not steady. It moves with FFB throughput, pond temperature and rainfall, so a fixed-speed set spends much of the year at 50–70% load — the zone where carbon builds up and the overhaul interval shortens. A brushless doubly-fed generator decouples engine speed from grid frequency: the engine can turn slower when gas is short and faster when it is plentiful, while the terminals stay at 415 V / 50 Hz. The same machine also motors: it can roll the engine up to ignition speed instead of being driven by a separate starter.
01 · No wear parts in the rotor
The rotor carries no windings, no slip rings and no carbon brushes. There is nothing to replace on a service interval, no carbon dust in a humid H₂S-bearing atmosphere, and no spark source next to the gas train.
02 · Variable speed
Speed can swing roughly ±30% while voltage and frequency stay fixed. When gas falls, the set turns slower and holds a healthy load factor instead of dropping into the carbon-building zone, tripping on lean burn or sending gas to the flare.
03 · Part-power converter
Only the slip power passes through the converter — typically 25–30% of rating — not the full 100% as with a permanent-magnet set. Smaller converter, lower conversion losses, fewer components carrying full current.
04 · Grid behaviour
The control winding can supply or absorb reactive power, synchronise with low inrush and ride through voltage dips — useful on weak rural feeders, long 415 V runs and island operation.
Motor ⇄ generator
A synchronous generator is a one-way device: its rotor is locked to grid frequency, it can only deliver power, and the breaker may only close when voltage, frequency, phase and phase sequence all match. A brushless doubly-fed machine is a motor and a generator in the same frame. Power flows both ways through the control winding: below synchronous speed it draws slip power to generate, above it the slip power is returned to the grid, and when the torque reverses it runs as a motor and drives the engine instead of being driven by it.
Boundary, stated plainly: the converter is sized for slip power, so motoring is a starting, barring and light-drive duty — not continuous full-torque drive. Long motor duty at large slip needs a larger converter; we size it per project and put the number in the quotation.
Four operating states
| Condition | State | Power flow |
|---|---|---|
| Below synchronous speed, driving torque | Motor | Grid → stator; slip power → control winding |
| Below synchronous speed, braking torque | Generator, sub-synchronous | Engine → stator; slip power taken from the grid |
| Above synchronous speed | Generator, super-synchronous | Engine → stator, slip power returned to the grid |
| Standing, engine stopped | Synchronous condenser | Reactive power only |
Crossing synchronous speed reverses the slip-power direction. That single change of sign is what makes the machine a motor on one side and a generator on the other — a synchronous machine has no such point because its speed is fixed.
| Item | Conventional synchronous + AVR | PM generator + full-power converter | Brushless doubly-fed (BDFG) |
|---|---|---|---|
| Slip rings / brushes | Carbon brushes, replaced periodically | None | None |
| Converter rating | Not applicable (AVR only) | 100% of generator rating | 25–30% of generator rating |
| Speed | Fixed by grid frequency | Variable | Variable, ≈ ±30% |
| Motor operation | None — generating only | Yes, full torque via converter | Yes — starting, barring and light drive |
| Synchronising | Precise synchronism required | Soft, via converter | Soft; breaker closes at any speed in range |
| Part-load behaviour | Below ~70% load, combustion quality and efficiency fall | Converter losses apply across the whole range | Engine stays in its efficient band at lower gas flow |
| Routine attention | Brush and slip-ring inspection, cleaning | Bearing and converter cooling | Bearing and converter cooling |
| Reactive power | Limited by the AVR | Via converter, good | Via control winding, good |
| Relative capex | Baseline | Higher | Between the two |
Indicative comparison, generator side only. BDFG is quoted as an option on 500 kW–2 MW units once the site gas profile is known. The continuous load range is set by the engine maker, not by the generator; the generator only removes the fixed-speed constraint.
Where it pays: mills where gas output is strongly seasonal, plants that spend months below 70% load, and remote sites where a brush change means a two-day outage and a fly-in technician. On a steady 100% base load with clean, stable gas, a conventional synchronous machine is still the cheaper answer — and we will say so.
Fuel gas
All values measured 1 m upstream of the gas pressure regulating valve. Outside these limits the engine is derated and warranty conditions change.
| Parameter | Requirement | Why |
|---|---|---|
| Gas temperature | 10 – 35 °C | Condensation and knock control |
| Gas pressure | 3 – 10 kPa(g); ramp ≤ 1 kPa/min | Stable mixing at the gas train |
| Dust | ≤ 5 μm; ≤ 10 mg/Nm³ | Valve and piston ring wear |
| H₂S | ≤ 50 mg/Nm³ | Acid corrosion of lube oil and liners |
| Gas humidity | ≤ 70% RH | No free water in the gas train |
| Condensate | None at lowest ambient temperature | Cold-start and winter operation |
| NH₃ | ≤ 40 mg/Nm³ | Formation of ammonium sulphates |
| Siloxanes | ≤ 10 mg/Nm³ | Abrasive silica deposits on valves and plugs |
| CH₄ | ≥ 45% by volume; ramp ≤ 2%/min | Stable combustion, no lean-burn trips |
Gas consumption
| Rating | CH₄ (Nm³/h) | Raw biogas at 45% | at 55% | at 60% | kWh per Nm³ CH₄ |
|---|---|---|---|---|---|
| 500 kW | 142 | 316 Nm³/h | 258 Nm³/h | 237 Nm³/h | 3.52 kWh |
| 600 kW | 172 | 382 Nm³/h | 313 Nm³/h | 287 Nm³/h | 3.49 kWh |
| 700 kW | 200 | 444 Nm³/h | 364 Nm³/h | 333 Nm³/h | 3.50 kWh |
| 1,000 kW | 286 | 636 Nm³/h | 520 Nm³/h | 477 Nm³/h | 3.50 kWh |
Manufacturer data: 142 / 172 / 200 / 286 Nm³ CH₄ per hour for 500 / 600 / 700 / 1,000 kW, i.e. ≈ 0.286 Nm³ CH₄ per kWh. Long-term output on variable biogas runs at 90–100% of rating, so annual energy should be modelled at 90% load.
Balance of plant
Capture
HDPE or geomembrane cover, headers, condensate traps, relief and hatches.
Desulfurisation
Trickling filter for bulk H₂S, polishing vessels in duty/standby.
Conditioning
Refrigerated dryer, coalescing filters, Roots blower with VFD, flame arrestor.
Storage
Membrane holder to buffer mill swings and protect the engine.
Safety
Full-flow flare, CH₄/H₂S detection, ESD logic, Ex-rated instruments.
Heat
Exhaust exchanger and jacket circuit to 85–95 °C hot water, or steam.
Scope matrix · biogas plant & upgrading
| Work package | KSTS / technology partner | Client | Notes |
|---|---|---|---|
| Process design & gas balance | Yes | Data supply | P&ID, GA, mass balance |
| Pond cover / digester | Design & supply | Site access, earthworks | Pond survey first |
| Gas treatment & gas train | Yes | — | Battery limit: engine inlet |
| Genset & control panel | Yes | — | Protection and synchronising |
| Civil foundations | Execution (CIDB) | Approvals | Local subcontractors |
| Electrical reticulation | Execution | Transformer / grid | 415 V; HV by utility |
| Erection & commissioning | Yes | Utilities | DOSH witness |
| O&M | Option | Site crew | Full contract or advisory |
Hydrogen CHP
Bottled 97% biomethane — or raw 60% biogas taken straight from the mill with an integrated purification front end — is reformed to hydrogen on site, then converted by a fuel cell into power and 60–70 °C hot water: no flame, no NOx, no SOx, no particulates. Water is the only by-product. FOB RM 10,000/kW for the bottled-gas version, installation excluded; the raw-biogas version is quoted per site.
| Model | Fuel input (kW) | CH₄ (Nm³/h) | Heat recovery (kW) | Hot water, 50 K rise (L/h) | Indicative price |
|---|---|---|---|---|---|
| 7.5 kW | 17.9 | 1.80 | 7.7 | 132 | RM 75,000 |
| 10 kW | 23.8 | 2.39 | 10.2 | 176 | RM 100,000 |
| 15 kW | 35.7 | 3.59 | 15.4 | 265 | RM 150,000 |
| 20 kW | 47.6 | 4.79 | 20.5 | 353 | RM 200,000 |
| 30 kW | 71.4 | 7.18 | 30.7 | 529 | RM 300,000 |
| 50 kW | 119.0 | 11.97 | 51.2 | 882 | RM 500,000 |
| 75 kW | 178.6 | 17.97 | 76.8 | 1,323 | RM 750,000 |
| 100 kW | 238.1 | 23.95 | 102.4 | 1,763 | RM 1,000,000 |
Basis: methane LHV 9.94 kWh/Nm³; 42% electrical and 43% recoverable heat are manufacturer guaranteed values at rated output (85% overall). Indicative FOB price to a Malaysian port, excluding freight, insurance, SST, installation, civil works, cylinder room, manifold and grid connection: RM 10,000/kW on bottled 97% gas, RM 19,500/kW on raw 60% biogas with integrated purification.
Feed gas
| Parameter | Requirement | Why |
|---|---|---|
| CH₄ | ≥ 95% by volume | Reforming catalyst needs a concentrated methane feed |
| H₂S | < 1 ppm | Sulphur poisons the reforming catalyst and the stack |
| Siloxanes | < 0.1 mg/Nm³ | Silica deposits on catalyst and electrodes |
| Condensate | None | Free water damages the catalyst bed |
| Supply | Bottled 97% gas at 200 bar via a manifold, or raw biogas at 55–65% through the integrated purification module | No pipeline and no on-site hydrogen storage |
| Raw biogas option | Desulphurisation, CO₂ removal, drying and compression inside the same package | No separate upgrading plant and no bottled gas needed; investment higher than the bottled-gas version |
Supply scope
| Item | Content |
|---|---|
| Included | Reformer, shift reactor, hydrogen purification, fuel cell stack, inverter, heat exchangers, control system, enclosure |
| Optional | Integrated front-end purification for raw biogas feed — desulphurisation, CO₂ removal, drying and compression inside the same package, priced per site |
| Excluded | SST, freight beyond a Malaysian port, civil works, cylinder room and manifold, installation, grid connection, permits |
| Warranty | 24 months on the unit; stack 5 years or 25,000 hours, whichever comes first |
| Delivery | 4–6 months from order and gas analysis |
| Price basis | Bottled-gas version FOB RM 10,000/kW; raw-biogas version with integrated purification FOB RM 19,500/kW. Both installation excluded, valid 90 days, subject to gas analysis and site survey. |
Scope matrix · hydrogen CHP
| Work package | KSTS / technology partner | Client | Notes |
|---|---|---|---|
| Sizing & load matching | Yes | Load profile | Sized on the heat and power demand |
| Fuel chain: upgrading, bottling, manifold — or raw biogas with integrated purification | Design & supply | Cylinder yard / pond gas tapping point | CH₄ ≥ 95% at reformer inlet, H₂S < 1 ppm |
| CHP unit & control panel | Yes | — | Battery limit: gas inlet and AC terminals |
| Civil foundations & enclosure | Execution (CIDB) | Approvals | Local subcontractors |
| Electrical & grid connection | Execution | Transformer / utility | 230/400 V; HV by utility |
| Erection & commissioning | Separate quotation | Utilities & access | Not included in the FOB price |
| O&M | Option | Site crew | Includes stack replacement planning |
| Permits & SST | Assist | Applicant of record | Per Malaysian regulations |
BHP air-conditioning
There is no electric motor in the drive train. A small gas engine turns an open-drive compressor directly, and the fuel is 97% biomethane from the mill’s own biogas — so the offices, laboratory and worker housing stay cool when the boiler, the turbine and the grid are all down. Engine jacket and exhaust heat is recovered at the same time as 60–90 °C hot water. Technology origin: gas-engine heat pumps were developed and industrialised by the former Sanyo air-conditioning division in Japan; the same class of machine is built in China by Dalian Sino-Tech Precision (Sino-Tech). BHP is that mechanical architecture with the fuel system re-adapted to mill biogas.
| Model | Cooling (kW) | Fuel input (kW) | CH₄ (Nm³/h) | Heat recovery (kW) | Hot water, 50 K rise (L/h) | Indicative price |
|---|---|---|---|---|---|---|
| BHP-30 | 30 | 30.0 | 3.0 | 7.5 | 129 | RM 75,000 |
| BHP-60 | 60 | 60.0 | 6.0 | 15.0 | 258 | RM 150,000 |
| BHP-120 | 120 | 120.0 | 12.1 | 30.0 | 517 | RM 300,000 |
| BHP-240 | 240 | 240.0 | 24.1 | 60.0 | 1,033 | RM 600,000 |
| BHP-480 | 480 | 480.0 | 48.3 | 120.0 | 2,067 | RM 1,200,000 |
Basis: cooling COP 1.0 on fuel LHV (typical 0.95–1.15; 1 Nm³ CH₄ ≈ 10 kWh of cooling); recoverable jacket + exhaust heat 25% of fuel input; fuel 97% CH₄, H₂S < 10 ppm, 5–20 kPa at the inlet. Indicative equipment price at RM 2,500/kW, excluding installation, civil works, ducts and cooling-water circuit. Units parallel to megawatt scale.
Included
Gas engine, open-drive compressor, evaporator and condenser, engine heat recovery, control panel and weatherproof enclosure.
Excluded
Civil foundation, chilled-water and duct distribution, gas line beyond the inlet flange, installation, SST and permits.
Fuel
Upgraded 97% biomethane from the mill’s own digester gas. No grid connection, no diesel tank, no electric chiller in the critical cooling path.
BHP system page