Engineering tools

Seven calculators, no sign-up

These are the formulas we use in pre-feasibility work. They are deliberately transparent: every assumption is shown and you can change it. Use them to challenge a supplier’s numbers — including ours.

Selection at a glance

Pick the model from the gas you measured

Enter the raw biogas flow and methane content from your own measurement. The selector returns the largest unit that runs on that gas at full load, plus the gas it needs and what it generates in a year.

Average over one to two weeks, not a peak reading.
Engine limit is 45% minimum.
Long-term output on variable biogas is 90–100%.
Recommended model—
Output at full load—
Pure methane required—
Raw biogas required at your CH₄—
Share of measured gas used—
Annual generation (8,000 h × load)—
Recoverable heat—
← 左右滑动查看完整表格 / swipe to see all columns
ModelCH₄ needed (Nm³/h)Raw gas @45%@55%@60%MWh/yr @90% loadHeat (kW)
500 kW1423162582373,600593
600 kW1723823132874,320718
700 kW2004443643335,040835
800 kW2295084163815,760954
1,000 kW2866365204777,2001,194

Based on manufacturer gas consumption (≈3.50 kWh per Nm³ CH₄), 8,000 operating hours and 90% load. Size on the 45% methane column when gas quality is uncertain — running out of gas costs more than buying one size larger.

Tool 01

Biogas flow → electricity and heat

Normal cubic metres per hour at 0 °C, 101.3 kPa.
POME biogas is typically 55–65%.
Manufacturer gas data: ≈3.50 kWh per Nm³ CH₄ = 35.2%. Premium European 40–43%.
Jacket + exhaust, typically 40–45%.
On variable biogas, long-term output is 90–100% of rating.

Results

Electrical output at full load—
Recoverable heat—
Fuel energy input—
Total efficiency (power + heat)—
Biogas per kWh generated—
Annual generation—
Annual heat delivered—
Diesel avoided—

Methane LHV 9.94 kWh/Nm³ (35.8 MJ/Nm³). Diesel genset at 35% efficiency and 2.68 kg CO₂/litre for the avoided-fuel figure.

Tool 02

Target output → gas demand

≈3.50 kWh per Nm³ CH₄ from manufacturer data.
Demand is calculated at full load; average scales with load.

Gas demand

Biogas at full load—
Biogas per day at full load—
Average at load factor—
Methane flow—
Fuel energy input—
Annual biogas—

Use this to test whether an offered engine matches your measured gas flow.

Tool 03

Mill throughput → biogas potential

Covered lagoon 20–28; well-mixed CSTR can reach 30+.
Share of generated gas actually delivered.

Biogas & power potential

POME produced—
Biogas generated—
Biogas to engine—
Methane available—
Electrical potential—
Annual generation (8,000 h)—

Assumes continuous 24-hour POME production. Real mills have shifts and stoppages — use measured inflow where available. Screening only, not a design basis.

Tool 04

Raw biogas → biomethane yield

PSA 95–98, membrane 96–99, water scrubber 98–99.

Upgrading output

Methane entering—
Biomethane product—
Methane in product—
Methane loss—
CO₂ removed—
Product energy (LHV)—
Upgrading power demand—
Diesel equivalent—

Product = CH₄ in × recovery ÷ purity. Diesel equivalent at 35.8 MJ/L LHV.

Tool 05

Project economics

Engine package FOB ≈ USD 580–630/kW (600–800 kW); complete plant typically USD 1,800–2,600/kW.
Inland Sabah diesel: RM 0.55–0.75. Grid import RM 0.40–0.50. Indonesia USD 0.07–0.10.
Only self-consumed kWh carry the full displaced-fuel value.
Full-service O&M incl. overhauls ≈ USD 0.017/kWh.

Financial summary

Total capex—
Annual generation—
Annual revenue—
Annual O&M—
Net annual cash flow—
Simple payback—
10-year net (undiscounted)—
NPV—
IRR (10 years)—
LCOE—

Revenue assumes the stated value for each valued kWh. Excludes financing, land and utility grid upgrades. Screening model, not bankable.

Tool 06

Hydrogen fuel-cell CHP → power, heat and gas demand

Range 7.5–100 kW per unit; parallel units above that.
97% for bottled biomethane; 60% if raw biogas with the integrated purification front end.
Manufacturer guarantee 42% at rated output (LHV).
50 K rise, 20 → 70 °C hot water.
Long-term output for a reformer + fuel cell: 85–100%.
FOB RM 10,000/kW for bottled 97% gas; RM 19,500/kW for raw 60% biogas with integrated purification.
Bottled biomethane RM 1.00–1.40. Own upgraded biogas ≈ RM 0.60 plus upgrading capex.
Grid 0.40–0.50; off-grid diesel 0.90–1.30. Enter the cost you actually avoid.
Set 0 if there is no year-round hot-water demand.
Stack replacement and service contract: 3–4% typical.

Sizing and annual performance

Recommended model—
Fuel energy input—
Methane required (Nm³/h)—
Fuel gas at your CH₄ (Nm³/h)—
Cylinders per day (50 L @ 200 bar ≈ 10 Nm³)—
Recoverable heat—
Hot water at 50 K rise—
Combined efficiency—
Annual generation—
Annual heat delivered—

Economics

Equipment cost (RM)—
Annual fuel cost—
Annual O&M—
Annual value of power + heat—
Net annual benefit—
Simple payback—
10-year NPV at 8%—
IRR (10 years)—
Cost per kWh generated—
CO₂ avoided—

Methane LHV 9.94 kWh/Nm³. Fuel input = output ÷ electrical efficiency; CH₄ flow = fuel input ÷ 9.94. Heat at 43% of fuel input, hot water at ΔT 50 K. CO₂ at 0.60 t/MWh of avoided grid power, biomethane carbon treated as short-cycle. FOB price, installation, civils, cylinder store and manifold excluded. Screening only.

Tool 07

Biogas heat-pump air-conditioning (BHP) → cooling without the grid

Offices, laboratory and worker housing; exclude process cooling.
Engine-driven class: 0.95–1.15 depending on ambient and part load.
97% biomethane is the standard fuel; raw biogas needs derating and shorter service intervals.
Indicative RM 2,500/kW cooling, installation excluded.
Own upgraded biogas ≈ RM 0.60/Nm³; bottled biomethane RM 1.00–1.40.
Grid 0.35–0.50; diesel-generated 0.90–1.60 once fuel logistics and downtime are counted.
VRF/chiller 2.8–3.5 in tropical conditions.
25% of fuel input is available as 60–90 °C water in cooling mode. Set 0 if unused.
Engine service, oil and filters: 3–4% typical.

Sizing and fuel demand

Recommended model—
Fuel energy input—
Methane required (Nm³/h)—
Fuel gas at your CH₄ (Nm³/h)—
Recoverable heat—
Hot water at 50 K rise—
Cooling delivered per year—
Fuel used per year—

Economics against the cooling it replaces

Equipment cost (RM)—
Annual fuel cost—
Annual O&M—
Electricity the old system would buy (kWh/yr)—
Cost of the old system—
Net annual saving—
Simple payback—
Cost per kWh of cooling—
Cost of the old system per kWh—
CO₂ avoided—

Methane LHV 9.94 kWh/Nm³. Fuel input = cooling ÷ COP; heat = 25% of fuel input in cooling mode; hot water at ΔT 50 K. The comparison system buys kWh from the grid or a diesel genset and makes cooling at the stated electric COP. CO₂ at 0.60 t/MWh. Indicative only — confirm COP and heat recovery against the model guarantee sheet.

Method & constants. Methane LHV 35.8 MJ/Nm³ = 9.94 kWh/Nm³. Biogas energy = flow × CH₄ fraction × 9.94. Electrical output = fuel energy × electrical efficiency. Recoverable heat = fuel energy × heat fraction. All results are indicative; guarantees are issued only against measured site data. Why we publish the formulas. Most supplier calculators hide their assumptions. A biogas project is decided on gas quality and operating hours, not on a polished number.