2Step 2: pick a module and calculate the savings potential
Water pump
⚙️ I. Plunger pump equipment parameters
Fill in from the ledger; average flow rate and input power are converted automatically
Electricity meter/Ledger reading; average input power is converted automatically
⚡ II. Efficiency parameters
Plunger pump overall efficiency reference 90% (our engineering basis ≥90%; can be changed per manufacturer sample)
Note: matching motor power is calculated automatically from flow rate and pressure.You do not need to enter the original pump efficiency——The system automatically back-calculates from “original condition effective power ÷ measured average input power“; results are listed directly in the details below.
0%
Overall energy-saving rate
0
Daily electricity savings kWh
0
Annual electricity savings 10k kWh
0
Annual electricity cost saving (10k CNY)
📊 Detailed calculation results
Project
Value
Get a free energy-saving retrofit technical solution Please contact the Zero Carbon Assistant; scan the QR code to add WeChat (QR code at the bottom of the page)
🔨 I. Mill equipment parameters
⚡ II. Efficiency parameters
Note: A higher load rate reduces no-load losses; PM synchronous motors are more efficient at low loads
0%
Overall energy-saving rate
0
Annual electricity savings 10k kWh
0
Annual electricity cost saving (10k CNY)
0
CO₂CO2 reduction (t)
📊 Detailed calculation results
Project
Value
Get a free energy-saving retrofit technical solution Please contact the Zero Carbon Assistant; scan the QR code to add WeChat (QR code at the bottom of the page)
🗜️ I. Air compressor parameters before retrofit
For screw compressors with load/unload control, the unloading period still consumes the rated power 25%~40% (default 35%). This no-load loss is the main energy-saving potential for VFD retrofits and centralized linkage control.
⚡ II. Retrofit plan (energy-saving rate calculated automatically from the parameters below)
VFD retrofit: first eliminate unload/idle losses, then convert using the screw compressor part-load power curve——VFD unit about 20% power is fixed loss (oil pump/fan/VFD), the remainder is roughly linear with air flow, so 50% air flow requires about 60% power (specific power degradation about 20%); constant-pressure control can further reduce discharge pressure; each reduction of 0.1 MPa shaft power drops about 7%.
⏱️ III. Operation and price
0%
Overall energy-saving rate (auto-calculated from operating parameters)
Overall energy-saving rate = Final result after item-by-item effects of all stages, not manually entered; a negative value indicates that this stage increases energy consumption (e.g., inverter losses).
♻️ Air compressor waste heat recovery (optional)
Project
Value
Approximately 90% of the air compressor’s input electrical energy is ultimately converted into heat, of which 70%~80% can be recovered for domestic hot water, heating, or process preheating (recovery rate ≥75% can produce 60℃ of hot water or above).
Get a free energy-saving retrofit technical solution
Please contact Zero Carbon Assistant; scan the QR code to add WeChat
Scan QR code to add WeChat · Free solution
♨️ I. Waste heat source parameters
Flue gas specific heat is usually taken as 1.30~1.45 kJ/(Nm³·℃); water specific heat 4.18 kJ/(kg ·℃).t₂ Must be above the acid dew point (coal-fired flue gas generally ≥120℃), to avoid low-temperature corrosion.
⚡ II. Recovery and utilization scheme
0 kW
Recoverable thermal power (effective)
0
Annual recovered heat GJ
0
Annual benefit (10k CNY)
0
CO₂CO2 reduction (t)
📊 Detailed calculation results
Project
Value
Get a free energy-saving retrofit technical solution
Please contact Zero Carbon Assistant; scan the QR code to add WeChat
Scan QR code to add WeChat · Free solution
🌬 1. Fan Parameters Before Retrofit
forced/induced/primary/dust removal/cooling fan main model
Fan maintained 101.3; for vacuum pumps enter actual absolute suction pressure (e.g. 40)
For vacuum pumps enter positive pressure difference (discharge−suction)
Nameplate power, for selection reference only
★ Enter this item and the original fan efficiency is calculated automatically; no need to understand efficiency
If measured input power is available → auto back-calculated; if not → use empirical value by original fan type (editable)
⚡ II. Fan Parameters After Retrofit
General low-voltage fan retrofitted to permanent-magnet integrated: overall efficiency ≥80% (reference value 82%)(auto-filled 82% / motor 97.6%)
⏱️ III. Operating Parameters
0%
Overall energy-saving rate
0
Annual electricity savings 10k kWh
0
Annual electricity cost saving (10k CNY)
0
CO₂CO2 reduction (t)
📊 Detailed calculation results
Project
Before retrofit
After retrofit
Savings
⚙️ Motor selection guidance
Project
Value
Notes
Selection principle:
1. Calculate shaft power = (Q × P) ÷ (3600 × 1000 × ηFan × ηTransmitted) [Unit:kW]
2. Recommended rated power = Calculate shaft power × safety factor (1.1-1.25)
3. Select standard power rating
Get a free energy-saving retrofit technical solution Please contact the Zero Carbon Assistant; scan the QR code to add WeChat (QR code at the bottom of the page)
💧 1. Water pump parameters before retrofit
If unsure, select the default; the system assigns an empirical efficiency by type
Nameplate power, for selection reference only
★ Fill in this item and the original pump efficiency is calculated automatically; no need to understand efficiency
If measured input power is available → auto back-calculated; if not → Empirical value by original pump type (editable)
Where efficiency comes from:Original equipmentEnter the measured motor input power; the system calculates by η = Effective power ÷ Back-calculated from measured input power (effective power = 9.81 × Flow rate × Head ÷ 3600); if no measurement is available, an empirical value is assigned by original pump type.New equipmentSelect the retrofit model directly below; the efficiency reference value is populated automatically.
⚡ II. Post-retrofit water pump parameters
Plunger pump overall efficiency ≥90% (industry sample 90~93%), replacing the main multistage centrifugal pump route (auto-filled 90% / motor 95.5%)
⏱️ III. Operating Parameters
0%
Overall energy-saving rate
0
Annual electricity savings 10k kWh
0
Annual electricity cost saving (10k CNY)
0
CO₂CO2 reduction (t)
📊 Detailed calculation results
Project
Before retrofit
After retrofit
Savings
⚙️ Motor selection guidance
Project
Value
Notes
Selection principle:
1. Calculate shaft power = (Q × H × 1000 × 9.81) ÷ (3600 × 1000 × ηPump × ηTransmitted) [Unit:kW]
2. Recommended rated power = Calculate shaft power × safety factor (1.1-1.25)
3. Select standard power rating
Get a free energy-saving retrofit technical solution Please contact the Zero Carbon Assistant; scan the QR code to add WeChat (QR code at the bottom of the page)
🪨 I. Slurry pump parameters before retrofit
Example model:4/3C-AH Centrifugal slurry pump(inlet×outlet 4×3 in, frame C / max. motor 30 kW, market designation “90 square pump“)——Nameplate rated flow rate 86.4 m³/h、head 9~52 m(example value 40 m), matched motor 30 kW; pump efficiency 48% is the slurry-condition value back-calculated from on-site measurements at the concentrator (nameplate clean-water efficiency 71%). Please modify according to the customer’s actual nameplate and measured data.
No need to guess the original pump efficiency:select “Back-calculate from measurements“, enter the current measured with a clamp meter (or the power meter reading), and the system will use ηPump = ρgQH ÷ (3.6×10⁶ × Pmeasured × ηPower × ηTransmitted) to back-calculateOriginal pump actual average efficiencyand fill it back in; if not measured, select “Use empirical value“ to get a default value by flow rate range, then correct it according to site conditions.
⚡ II. Slurry pump parameters after retrofit
Plunger slurry pump overall efficiency reference 88% (slurry duty, positive displacement); impeller/Efficiency decay after liner wear is far smaller than centrifugal type
Four common retrofit paths for slurry pumps:
① Plunger slurry pump replacement (primary recommendation)——Positive displacement work, overall efficiency in slurry duty can be taken as 85%~90% (centrifugal on-site mostly 45%~55%); valve group/seal/Plunger wetted parts life is typically 2~3 times that of centrifugal impeller and liner, and efficiency decays slowly after wear; advantages are most obvious in high-concentration, high-head duties;
② High-efficiency hydraulic model / Whole-pump replacement——Centrifugal efficiency raised from 60%~65% to 72%~78% (while also improving the material and wear life of wetted parts);
③ Variable frequency drive——When the operating flow rate is persistently below the rated value (or needs to be adjusted according to ore throughput), apply the affinity laws Q∝n, H∝n², P∝n³ to reduce speed;
④ Impeller trimming / reduce speed——When the head is persistently excessive, trim the impeller outer diameter instead of throttling with valves or recirculation.
⚠️ When reducing flow rate, verify thecritical settling velocity(generally 1.5~2.5 m/s; use the higher value for coarse particles), and do not fall below the deposition velocity, otherwise the pipe will clog.
⚠️ Sizing note:This page calculates shaft power based on P = ρ·g ·Q ·H ÷ (3.6×10⁶ × ηPump × ηTransmitted) calculation. When selecting aplunger slurry pumpthe system automatically converts the outlet differential pressure ΔP = ρ·g ·H (MPa), equivalent to P = Q × ΔP ÷ (3.6 × ηPump); the results will list it separately ΔP for model selection.
⏱️ III. Operation and price
0%
Overall energy-saving rate (based on motor input power)
0
Annual electricity savings 10k kWh
0
Annual electricity cost saving (10k CNY)
0
CO₂CO2 reduction (t)
—
Static payback period, years
—
Retrofit investment (10k CNY)
—
Power consumption per ton of dry ore kWh/t
📊 Detailed calculation results
Project
Before retrofit
After retrofit
Savings
Shaft power P = ρ × g × Q × H ÷ (3.6×10⁶ × ηPump × ηTransmitted) (ρ: kg/m³;Q: m³/h;H: m); motor input power = Shaft power ÷ ηPower.
Slurry density converted by solids content:ρ = 1 ÷ (Cw/ρs + (1−Cw)/1000), Cw is the mass fraction.
⚙️ Motor selection guidance
Project
Value
Notes
Selection principles (slurry pump)
1. Calculate shaft power based onmaximum slurry densityandmaximum flow rateoperating conditions; do not use average conditions;
2. Recommended rated power = Calculate shaft power × safety factor (1.15~1.30,for slurry pumps take the larger value, leaving margin for wear and concentration fluctuations);
3. Head must include 10% approximately wear allowance/fouling margin;
4. Motor protection rating not lower than IP55,for humid and dusty conditions recommend IP65and verify the maximum particle passing capacity and the material of wetted parts.
Get a free energy-saving retrofit technical solution Please contact the Zero Carbon Assistant; scan the QR code to add WeChat (QR code at the bottom of the page)
🛡 Why plunger slurry pumps are recommended to replace centrifugal slurry pumps
Valve assembly / seal / Plunger 12 months or more; wetted parts life is typically 2~3 times that of centrifugal pumps
Efficiency decay
Efficiency drops rapidly after impeller wear, often by 10 percentage points or more
Positive displacement operation; wear has little effect on flow rate, so efficiency decays slowly
High concentration / High head
When concentration and head rise simultaneously, efficiency and life deteriorate together
Solids content 30% Above this, the advantage is most pronounced in high-head scenarios
Energy consumption
Clear-water efficiency 71%~78%common in slurry conditions 45%~55%
Whole-unit efficiency under slurry conditions 85%~90%
Control method
Throttle valve / Variable frequency / Impeller trimming
Variable speed or variable stroke; low-flow conditions are less prone to overpressure
The above is an industry experience range and not a contractual commitment; actual service life and model selection must be verified on site based on slurry particle size, abrasiveness, concentration, and operating regime.
Get a free energy-saving retrofit technical solution
Please contact Zero Carbon Assistant; scan the QR code to add WeChat
Scan QR code to add WeChat · Free solution
⚡ I. Motor and operating parameters (mixer-type mechanical transmission loads)
Selecting a type auto-fills efficiency and reference unit price; editable; same loss-separation model, differences in full-load efficiency and unit price
Why a separate “Mechanical transmission load“ module:Loads such as mixers, internal mixers, and screw conveyors belong toConstant torque load——The required torque is essentially constant, and power varies linearly with speed. Its energy-saving mechanism is completely different from that of fans and pumps (quadratic torque, where power varies with the cube of speed):Constant torque loads cannot save much energy through variable-frequency speed control; the real energy-saving opportunity lies in the efficiency and power factor of the motor itself under light-load conditions.
How to estimate the load factor:If a power meter is available, read it directly (actual power ÷ rated power); if only a clamp meter is available, estimate by P ≈ √3 × U × I × cosφ ; if neither is available, for mixer-type loads you can initially use 30%~50% , which is a common range.This item has the greatest impact on the result; it is recommended to verify after actual measurement.
Scope boundaries of this calculation:Only includemotor replacementefficiency gains; excludes VFD replacement, gearbox and mixer body modifications, and process optimization.Permanent magnet synchronous motors must be driven by a VFD that supports permanent magnet vector control; if the existing VFD does not support this, the investment in a high-voltage VFD must be counted separately (for this project scale, approximately 30~50 10k CNY), and the economics must then be re-evaluated.
--%
Estimated energy-saving rate (base case)
--
Annual electricity savings (10k kWh)
--
Annual electricity savings (10k CNY)
--
Static payback period (years)
Physical upper limit of the energy-saving rate:Motor efficiency improvement is constrained by thermodynamics and electromagnetic design;the upper limit of the energy-saving rate for a like-for-like replacement is about 2%~9%depending on the original motor’s efficiency class, aging degree and slip ring condition. Any claim that a single replacement can reach 15%~30% usually combines the benefits of “motor replacement + Variable frequency drive + system retrofit“ into one figure, or compares against a long-failed old motor. This tool does not merge such scopes.
Investment basis:Equipment price is estimated in CNY/kW, tax included; installation and commissioning cost is 15% of the equipment price (including old unit removal, lifting, alignment, electrical wiring, VFD setting). Actual prices vary with power rating, voltage class, protection class and whether an encoder is included; refer to the manufacturer’s formal quotation.
Maintenance benefit basis:Carbon brush and slip ring maintenance for wound-rotor motors (including sparking downtime losses in dusty environments) is estimated at 1.0~2.0 10k CNY/per year, already included in the payback period. Squirrel-cage motors have no such item; only electricity cost savings are counted.
Need a technical proposal for your equipment?
The calculation on this page is the complete result; you can screenshot or print it for your records. To obtain a retrofit technical proposal, equipment selection and quotation based on your site conditions, please contact the Zero Carbon Assistant.
Please contact Zero Carbon Assistant; scan the QR code to add WeChat
Scan QR code to add WeChat · Get technical proposal
🩺 1. Equipment profile
Used to assess voltage deviation; enter per nameplate
🔧 2. Mechanical operating parameters
⚡ III. Electrical operating parameters
Any phase with a clamp meter
Voltmeter reading
📈 IV. Energy efficiency operating parameters (must be measured · fill in by equipment type)
Preliminary directional assessment based on public standards: vibration severity ISO 10816 / GB/T 6075; winding temperature GB/T 755 insulation class limit; three-phase unbalance GB/T 755; energy efficiency is estimated by effective power (pump/Fan/air compressor) or motor efficiency to estimate shaft power. Results are directional reference only, not equipment diagnostic conclusions.
Quick assessment: vibration severity · winding temperature · voltage deviation · current and power matching · load rate · power factor · unit overall efficiency,1 directional preliminary judgment in minutes. Unit efficiency requires actual measurement——flow rate, pressure, and efficiency are required (pump/Fan/air compressor by type). Switch to “Full Assessment“ when noise, three-phase imbalance, speed, or specific power is needed.
—
overall health grading (strictest item applies)
0
number of criteria items
0
warning / abnormal items
—
unit overall efficiency
—
estimated shaft power kW by pump efficiency 70%
current mode:⚡ quick assessment (6 key indicators)
📊 item-by-item criteria
category
Project
measured
criteria
Conclusion
🔎 Suspected areas
🛠 Recommended actions
➡️ Next step: calculate the energy-saving potential of this equipment
Current status has been assessed (energy efficiency, mechanical and electrical conditions)→ Select the corresponding equipment to calculate the energy-saving rate, annual energy savings and payback period after retrofit.
Get a free energy-saving retrofit technical solution
Please contact Zero Carbon Assistant; scan the QR code to add WeChat
Scan QR code to add WeChat · Free solution
⚠️ Scope statement
This platform is an engineering calculation aid; results are for reference only, and actual retrofit projects must be based on site surveys and verified data. The platform is a web-based, installation-free tool and does not constitute any commitment or offer to transact.
📞 Get a free energy-saving retrofit technical solution
Please contact Zero Carbon Assistant 18041136555 Scan the QR code to add us on WeChat for a free proposal
Industrial energy-saving retrofit · Pump and fan systems · Waste heat and pressure utilization · Equipment health management
🛠 Technical foundation · Industrial edge agent
Behind this platform is an “industrial edge agent“ technology: connectingequipment mechanisms + edge inference + agent orchestrationinto a single pipeline,
enabling fans, water pumps, and compressors"to diagnose, save power, and communicate"——works offline, data never leaves the site.
includes rotating machinery mechanism simulation, a complete diagnostic pipeline demo, and diagnostic message contracts; runs on a domestic edge computing box (RK3576 · NPU).
for university co-built training labs and intelligent equipment-factory integration.